This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| multimeter [2024/08/19 16:24] – herman | multimeter [2025/10/21 15:30] (current) – [Extra functies.] herman | ||
|---|---|---|---|
| Line 3: | Line 3: | ||
| Super krachtig ding die onder andere uA kan meten (laag stroomgebruik, | Super krachtig ding die onder andere uA kan meten (laag stroomgebruik, | ||
| - | De reputatie is dat zo'n ding precies is, in 2024 is hij mee geweest naar Maker Faire Hannover waar hij een "Maker calibratie" | + | ====== Extra functies. ====== |
| + | Als je tijdens aanzetten een van de knoppen 2 seconden lang indrukt zijn er extra opties beschikbaar: | ||
| + | * blue: disable automatic power-off | ||
| + | * min max: hi accuracy, 1 sec. response | ||
| + | * range: test rotary switch | ||
| + | * hold: ultrasonic data output (For use in factory testing only) | ||
| + | * yellow: 4 1/2 digit display. < | ||
| + | * ))): turn off beeper | ||
| + | * Hz: hi impedance mV DC input | ||
| - | ^ Range ^ Verwacht ^ Uitkomst | + | ====== Calibratie ====== |
| - | |mV | 10 | 0.010 | | + | |
| - | |mV | | | | + | |
| - | |V |1 | | | + | De reputatie is dat zo'n ding precies is, en dat is hij ook. In 2024 is hij mee geweest naar Maker Faire Hannover waar hij een "Maker calibratie" |
| - | |V |10 | | | + | |
| - | |V |100 | | | + | |
| - | |Ac | | | | + | ^ **Range** ^ **Verwacht** ^ **Resultaat** |
| - | | | | | | + | |DC mV | 10 | 0.010 | |
| - | | | | | | + | |DC mV | 100 | 0.100 | |
| - | | | | | | + | |DC V |1 | 1| |
| - | | | | | | + | |DC V |10 | 10.00| |
| - | | | | | | + | |DC V |100 | 100.0| |
| - | | | | | | + | |AC V 1kHz | 10 | 10.03| |
| - | | | | | | + | |AC V 1kHz | 230 | 229,9| |
| - | | | | | | + | |DC uA | 1| 1.1| |
| - | | | | | | + | |DC uA | 10 | 10.2| |
| + | |DC uA | 100 | 100.1| | ||
| + | |DC uA | 1000 | 999| | ||
| + | |DC mA | 10 | 10.01 | | ||
| + | |DC mA | 100 | 100.0 | | ||
| + | |DC mA | 200 | 200.0 | | ||
| + | |DC A | 1 | 1000mA | ||
| + | |DC A | 4 | 4 | | ||
| + | |AC mA | 100 | 100.3| | ||
| + | |AC mA | 200 | 200.2| | ||
| + | |Ω |1 | 1.1| | ||
| + | |Ω |10|10.1| | ||
| + | |Ω |100|100.1| | ||
| + | |Ω |1k|1.000k| | ||
| + | |Ω |10k|10.00k| | ||
| + | |Ω |100k|99.9k| | ||
| + | |Ω |1m|1.000m| | ||
| + | |Ω |10m|10.00m| | ||
| + | |||
| + | |||
| + | {{2024_fluke_fluke_en_fluke.jpg? | ||
| + | |||
| + | Op de pijnbank. | ||